CAD模型選擇
{baumer/products/processsensors/levelmeasurement/pl20_asmtab.prj},{NB=Baumer_PL20S_11227160},{AN=11227160},{WT=120},{DIST=4},{VER=Adaptive trigger},{TM=Adaptive trigger | Adaptive trigger},{OS=PNP | PNP},{IFC=IO-Link 1.1},{DOP=IP67, with appropriate cable | IP69K, with appropriate cable},{ELC=M12-A, 4-pin, polycarbonate},{CL=Without cable},{PTR=-40 ... 115 °C, continuous @ Tamb < 50 °C | -40 ... 135 °C, < 1 h @ Tamb < 50 °C},{PRP=-1 ... 10 bar | -1 ... 5 bar, T = 135 °C},{PC=G 1/2 A hygienic (A03)},{PCM=AISI 316L (1.4404)},{SUR=Ra ≤ 0.8 µm},{MGE=Without},{MSI=NBR},{EX=Without},{AP=EN 1935/2004 | EN 10/2011 | EN 2023/2006 | FDA | cULus listed, E365692},{CONF=Factory settings},{TC=PL20S-11111.111012.A03021010000},{TCX=PL20S},{WS=icon_website.png}
請根據技術需求選擇所需產品. 可選屬性在表格中高亮顯示. 選擇可以通過點擊表格或數值來重置.
PL20S-11111.111012.A03021010000
HELP_VARIABLE
Company
Baumer Group
Description
PL20 - Point level detection based on frequency deviation technology
Bill of material
PL20S-11111.111012.A03021010000
VER
Version
Adaptive trigger
TM
Trigger modes
Adaptive trigger | Adaptive trigger
Adaptive trigger | Adaptive trigger
OS
Output signal
PNP | PNP
PNP | PNP
IFC
Interface
IO-Link 1.1
DOP
Degree of protection (EN 60529)
IP67, with appropriate cable | IP69K, with appropriate cable
IP67, with appropriate cable | IP69K, with appropriate cable
ELC
Electrical connection
M12-A, 4-pin, polycarbonate
M12-A, 4-pin, polycarbonate
CL
Cable length
without cable
PTR
Process temperature
-40 ... 115 °C, continuous @ Tamb < 50 °C | -40 ... 135 °C, < 1 h @ Tamb < 50 °C
-40 ... 115 °C, continuous @ Tamb < 50 °C | -40 ... 135 °C, < 1 h @ Tamb < 50 °C
PRP
Process pressure
-1 ... 10 bar | -1 ... 5 bar, T = 135 °C
-1 ... 10 bar | -1 ... 5 bar, T = 135 °C
PC
Process connection
G 1/2 A hygienic (A03)
G 1/2 A hygienic (A03)
PCM
Process connection material
AISI 316L (1.4404)
SUR
Surface roughness
Ra ≤ 0.8 µm
Ra ≤ 0.8 µm
MGE
Gasket material (external)
without
without
MSI
Sealing-/ O-ring (internal)
NBR
NBR
EX
Explosion protection
without
AP
Compliance and approvals
EN 1935/2004 | EN 10/2011 | EN 2023/2006 | FDA | cULus listed, E365692
EN 1935/2004 | EN 10/2011 | EN 2023/2006 | FDA | cULus listed, E365692
CONF
Configuration
Factory settings
TC
Typecode
PL20S-11111.111012.A03021010000
PL20S-11111.111012.A03021010000
AN
Articlenumber
11227160
11227160
WS
Website
EP
EPLAN
HYS
Hysteresis
± 1 mm
REP
Repeatability
± 1 mm
MC
Media characteristics
DC > 1.5
SRT
Step response time
< 150 ms
DAMP
Damping
0 ... 10 s , adjustable
MWP
Wetted parts material
PEEK Natura | AISI 316L (1.4404)
OTR
Operating temperature range
-40 ... 85 °C
-40 ... 85 °C
CC
Voltage supply range
8 ... 35 V DC
CONS
Current consumption (no load)
25 mA, typ. | 53 mA, max.
OC
Current rating
100 mA, max.
WT
Weight
120
120
g